We cover T101, T103 and T104 models of mechanical pool timers. Yes, likely a short to ground. I would suggest calling Intermatic and suggesting that idea and a free replacement? Switch the breaker off at the power board. Hello. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. Hi Bev, seems legit to me! Im ready to send my back for a replacement. We may earn a small commission. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Ive got a weak pump battery so every time the mechanism shuts off it looses time. A timer replacement would be required. Timer must be reset for current time after power outage. Hello, newer pool guy here. Until it came in, I manually turned on and the tripper turned it off. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Did I wire it incorrectly or did I just get a bad timer? I have a sweeper set on auto on the second timer and it is working correctly. With this model can I control both of these motors with two different on and off times. Breakers go bad sometimes, after many years. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. If the pump comes on, you definitely have power to the timer. Timer not tripping pump on. Thanks. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. I replaced the fuse(BUSS 300v GLR 3) as well. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Jump to the troubleshooting steps below to fix the issue. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. As it get cooler you can cut it down to 5 or 6 hr a day . How do you know if your pool timer is bad? The clock not turning on your Intermatic pool timer is a common issue. Thank you. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. For Sale: 2 beds, 2 baths 1152 sq. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. You will have live wires exposed and they can kill you if you touch them. Now, Im going to order some additional timer clips. It was always fine before. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Line is incoming, Load goes to the pump. Should You Get a Pool Pump Timer? If your pool pump timer is beyond repair, call a professional to replace it. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. I have a 2 speed pump. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. You dont have two OFF trippers, right? Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . "dateModified": "1/10/2020",
Paul, it could be that you got a 50hz motor, instead of a 60hz? To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. Inside, the 1 gear on the right side can be removed to access a metal bar. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Ft. 750 Joshua Dr, Hollister, CA 95023. Just installed a new timer. I have the Intermatic T103 autotimer on my pool. You will first want to look at the pool timer and see if you have two timer pins. Morgan Burley Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. I used to run the pump for 8-9 hrs a day. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Thanks! Hi, Davy, seeing lots of complaints here. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Any guidance on how to fix this? That should quiet it down. Donna Simpson Eating Website But What Toilet? It should loosen up after a few goes when the grease and gunt dissolve. P.S. I dont see any debris blocking the off dog. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. If you are not sure if your timer is working or not you will first need to know if its even operational. I just replaced my T101 timer 2 years ago. These clocks determine when your pool pump turns on, and how long it runs. Ive seen it happen from lightning strikes, or insect infestation. BUILT BY HAND IN QUEENS, NYC. Reset the clock to the correct time. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. i have an oval pool that is closed for the winter but there ha been a problem. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . You can have as many ON an OFF trippes as you want. Your email address will not be published. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Rich. . You should be able to see the gears moving. If I have to tell you which terminals to measure, you shouldnt be doing this! Here are some pictures. the problem lies, where the power dies as they say. Ask Your Own Pool and Spa Question Hi Davey, Wont power on pump but can hear timer clicking away. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Now The ice and snow have melted and the cover is getting in deeper. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Ive got the opposite problem than a lot of people. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper.
Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow Sometimes old power wires split or short-out. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. Did you try to flip the switch of the timeclock? Help! If the pool timer is not keeping the correct time or losing time, there may be a simple fix. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. My pool pump timer is not working properly. Turn the metal bar until it contacts one of two plastic side tabs.
1100 Juanita St, Austin, TX 78704 | MLS #6354744 | Zillow "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
A power surge may have taken out the timer or the pump. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Is it Necessary? If you dont have the voltage here you have an issue with either the wiring or the breaker. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. any suggestions about how i might avoid another situation like the above would be appreciated. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Second thing to check is the dial bent or warped, in that area where the on tripper is? There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Some white lithium grease on the switch can help in some cases. This is the first step to confirm if there is power or not. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Wired correctly, #10 wire, nothing. You can replace the entire mechanism or the gears. Replace them if they appear to be bent. Faulty Pump or Wiring from the Timer to the Pump. At some time the timer was disconnected and the pump wired direct to the breakers. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. I think I have found it. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Set the current time to the center time pointer, pointing downward at 6 oclock. Does the manual lever stay in the on position always? I dont see timer gears rotating on any power going to the pump or salt system. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. Sound right? Did you find the issue? Hi Jere, that could be the timer motor failing. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Below is a breakdown of how to wire different Intermatic timer models. Elite. How about the GFCI outlet TEST button, is it tripped? Pool Timer Not Turning ON or OFF!! Also be sure that the front dial is engaged with the gear located behind the dial. Date Listed: 18/02/2023; . I have a T104. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). No luck. Terminals 2 and 4 are used for wires going to the load (pump). Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! A couple of weeks in, I noticed it was not keeping time. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Is the ON tripper all the way pushed onto the dial? I am using the breaker to turn on and off the pool pump. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. If I manually push the lever, it moves without much pressure. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Thank you so much. You can replace it but its really just easier to replace the entire mechanism. Hi. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty.
What Causes Problems With Intermatic Timers? - Reference.com I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. More. Posted by 4 years ago. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Hey there!
And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. Resolved! It only takes a small amount of dirt to foul up gears so look carefully. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Stupid third question, but does the ON tripper say ON? Step 3 The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Does the tripper work on other areas of the clock, like near the off tripper? Refer to the wiring diagram on the timer door for more information. Please let me know if you find the solution! The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? },
12 Best Pool Pump Timers For Reducing Your Power Bill! Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Or may be bent and not come together. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. They should be straight, if not, replace them. My time clock has an ant infestation! Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.)
7 Best Pool Pump Timers (Winter 2023) - Reviews & Buying Guide It started lagging again a week or so ago. Take them off and inspect them. This will disengage the dial and allow you to spin it in either direction. Replace a new T104. March 16, 2022 by WildRiverCountry. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. You off course will want to adjust one time pin at a time. You can check these easily by removing them and inspecting them for damage. Everythings OK now, unit works just fine. Check the wire connections to be sure they are tight, and look for any burnt wires. Theres power to the pump using the manual override. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? How can I fix this? the trippers are even slightly damaged the timer won't work correctly. Thanks.
Garden Guides | How to Troubleshoot a Swimming Pool Timer Or is there anything else I can check? ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Power surges could be to blame. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. Read full answer 2/14/2023 3:20:07 AM This site is owned and operated by AJH Trade Group. I unscrewed the clip and put it back on and its still doing the same thing. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. Dead as a door nail. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Turn on / off manually work fine, but The clock gears still not moving. Any advice on how to fix. I took the electrical box cover off and check the breaker connections. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. It should be 110V or 220V AC. Lately, the timer mechanism on my old T104R does not move. I flicked the switch between on and off and it will not shut off. Is it keeping time normally? do i need to do something different? There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/.
Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. You should always be able to switch your pump on and off manually at the timer.